Chemical-membrane pump MZ 2C NT + AK

VACUUBRAND

Type Dimensions (W x D x H) mm max. discharge flow m³ / hr. Ultimate vacuum without / with gas ballast mbar (abs.) Connector PK
Purchase order number
6234067
Cat. No. Type Dimensions (W x D x H) mm max. discharge flow m³ / hr. Ultimate vacuum without / with gas ballast mbar (abs.) Connector PK

1

4665353 PC 510 select 243 x 418 x 457 2.0 / 2.3 7 / 12 CEE 1
4670345 MD 1C + AK + EK 239 x 316 x 405 1.3 / 1.5 2 / 4 UK 1
4670445 MZ 2C NT + AK + EK 242 x 319 x 309 2.0 / 2.3 7 / 12 UK 1
4670449 MZ 2C NT + AK SYNCHRO + EK 243 x 310 x 313 2.0 / 2.3 7 / 12 UK 1
4670456 PC 510 select 243 x 418 x 457 2.0 / 2.3 7 / 12 UK 1
4670462 PC 511 select 243 x 435 x 457 2.0 / 2.3 7 / 12 CH 1
4670463 PC 511 select 243 x 435 x 457 2.0 / 2.3 7 / 12 UK 1
4670469 PC 520 select 243 x 435 x 457 2.0 / 2.3 7 / 12 CH 1
4670470 PC 520 select 243 x 435 x 457 2.0 / 2.3 7 / 12 UK 1
4670506 MD 4C NT + AK + EK 248 x 326 x 402 3.4 / 3.8 1.5 / 3 UK 1
4670516 PC 610 select 243 x 419 x 457 3.4 / 3.8 1.5 / 3 CEE 1
4670517 PC 610 select 243 x 419 x 457 3.4 / 3.8 1.5 / 3 CH 1
4670518 PC 610 select 243 x 419 x 457 3.4 / 3.8 1.5 / 3 UK 1
4670525 PC 611 select 243 x 435 x 457 3.4 / 3.8 1.5 / 3 CEE 1
4670526 PC 611 select 243 x 435 x 457 3.4 / 3.8 1.5 / 3 CH 1
4670527 PC 611 select 243 x 435 x 457 3.4 / 3.8 1.5 / 3 UK 1
4670533 PC 620 select 243 x 435 x 457 3.4 / 3.8 1.5 / 3 CEE 1
4670534 PC 620 select 243 x 435 x 457 3.4 / 3.8 1.5 / 3 CH 1
4670535 PC 620 select 243 x 435 x 457 3.4 / 3.8 1.5 / 3 UK 1
6231821 MZ 2C NT + AK + M + D 243 x 310 x 313 2.0 / 2.3 7 / 12 CEE 1
6234067 MZ 2C NT + AK + EK 242 x 326 x 402 2.0 / 2.3 7 / 12 CEE 1
6241292 PC 201 NT 243 x 326 x 402 3.4 / 3.8 1.5 / 3 CEE 1
6245040 MD 4C NT 248 x 326 x 402 3.4 / 3.8 1.5 / 3 CEE 1
6260612 MZ 2C NT + AK + EK PELTRONIC 243 x 326 x 402 2.0 / 2.3 7 / 12 - 1
6274327 PC 510 select 243 x 418 x 457 2.0 / 2.3 7 / 12 CH 1
6701344 PC 101 NT 243 x 326 x 402 2.0 / 2.3 7 /12 CEE 1
7983628 PC 520 select 243 x 435 x 457 2.0 / 2.3 7 / 12 CEE 1
7983629 PC 511 select 243 x 435 x 457 2.0 / 2.3 7 / 12 CEE 1
9880828 MD 1C + AK + EK 239 x 316 x 405 1.3 / 1.5 2 / 4 CEE 1
9880832 MZ 2C NT + 2AK 243 x 319 x 309 2.0 / 2.3 7 / 12 CEE 1
9880837 MD 4C NT + AK + EK 243 x 326 x 402 3.4 / 3.8 1.5 / 3 CEE 1
9880844 MZ 2C NT + 2AK 242 x 319 x 309 2.0 / 2.3 7 / 12 CH 1
9880921 MZ 2C NT + AK SYNCHRO + EK 243 x 326 x 402 2.0 / 2.3 7 / 12 CEE 1
9880922 MZ 2C NT + AK SYNCHRO + EK 248 x 326 x 402 2.0 / 2.3 7 / 12 CH 1
9880923 MZ 2C NT + AK + EK 242 x 326 x 402 2.0 / 2.3 7 / 12 CH 1
9880924 MD 4C NT + AK + EK 242 x 326 x 402 3.4 / 3.8 1.5 / 3 CH 1
9880925 MD 1C + AK + EK 239 x 316 x 405 1.3 / 1.5 2 / 4 CH 1
9880965 MD 12C NT + EK 387 x 528 x 395 12.0 / 13.3 2 / 4 CEE 1
9880966 MD 12C NT + EK 387 x 528 x 395 12.0 / 13.3 2 / 4 CH 1
9880967 MD 12C NT + EK 387 x 528 x 395 12.0 / 13.3 2 / 4 UK 1
9880968 MD 12C NT + AK + EK 387 x 616 x 395 12.0 / 13.3 2 / 4 CEE 1
9880969 MD 12C NT + AK + EK 387 x 616 x 395 12.0 / 13.3 2 / 4 CH 1
9880970 MD 12C NT + AK + EK 387 x 616 x 395 12.0 / 13.3 2 / 4 UK 1
9880976 MV 10C NT + EK 528 x 387 x 395 9.5 / 10.7 0.9 / 1.5 CEE 1

Compact design, ready to use, no set-up required. Constructed in chemically resistant materials. Quiet operation.

  • 100% oil-free pumping of gases
  • gas ballast as standard for working with condensable vapours
  • good vacuum even with gas ballast
  • high vapour tolerance for water and solvents
  • long service life, low maintenance

Features:
2AK:
Inlet and outlet separator
AK + EK: Inlet separator, exhaust vapour condenser
PC 510 select (two-stage) / 610 select (three-stage) : with AK + EK; 1 electronically controlled vacuum port
PC 511 select (two-stage) / 611 select (three-stage) : with AK + EK; 1 electronically controlled and 1 manually controlled vacuum port
PC 520 select (two-stage) / 620 select (three-stage) : with AK + EK; 2 electronically controlled vacuum ports

Characteristics and applications:
Without vacuum control:
MZ 2C NT +2AK: e.g. filtration, distillation without condensation at the outlet
MZ 2C NT +AK+EK: Well-proven unit for a wide range of applications for a single-user, e.g. gel drying, distillation, vacuum concentrator. For solvents with medium to low volatility.
MD 1C +AK+EK: Space-saving single-user configuration. For high-boiling-point solvents.
MD 4C NT + AK+EK: Larger or multi-user applications, the local vacuum network VACUU·LAN®. For high-boiling solvents.
MV 10C NT +EK: Four-stage diaphragm pump with exhaust vapour condenser. For particularly high demands regarding low ultimate vacuum and pumping speed in chemistry laboratories, pilot plant or small production units.

With vacuum controller:
PC 510 select / 511 select: Well-proven units for a wide range of processes in chemistry laboratories, e.g. all common solvents. PC 511 select with addtional manually controlled vacuum port.
PC 610 select / 611 select: Proven solution for supporting electronically controlled evaporation or drying processes even with many high boiling point solvents. PC 611 select with additional manually controlled vacuum port.
PC 520 select / 620 select: Compact solution for simultaneous operation of two electronically controlled vacuum applications with one single pump.

Alternatives